Automotive Electronic Control Unit Ground Line Health Monitoring Method

##plugins.themes.bootstrap3.article.main##

##plugins.themes.bootstrap3.article.sidebar##

Published Oct 26, 2023
Alaeddin Milhim Hadyan Ramadhan Xinyu Du Shengbing Jiang Hossein Sadjadi

Abstract

Electronic Control Units (ECUs) have been used in the automotive industry for decades to control one or more of the vehicle subsystems. The ECUs communicate primarily using the in-vehicle Controller Area Network (CAN) communication protocol. The recent rapid development of connected, electric, and autonomous vehicles expands the number of ECUs and complexity of the CAN network required to integrate vehicle systems and deliver the desired functionalities. This demands increased reliability of the ECUs to ensure for robust vehicle performance. One of the most common ECU failure modes is the ECU ground fault. A ground fault occurs when the ground path in the ECU circuit is corroded, which is usually developed slowly over time. Such failure usually results in various symptoms including ECU incapable of functioning and further impacts the vehicle functionalities negatively. This type of fault can be difficult to detect prior to vehicle functionality loss. It usually involves routinely testing the resistance of the ground circuit, visually inspecting the connectors and wirings, and checking the voltage drop across the ground circuit. Therefore, it is highly desirable to continuously monitor the ECU ground line health status to predict any degradation and thus prevent vehicle functionality losses.

This paper presents a novel method to monitor the health status of ECU ground line. The method leverages measured CAN voltage data to estimate the ECU ground state of health. The CAN voltage measurements are preprocessed and fed into a real-time data buffer of predefined size. Statistical moments are calculated from the buffered data to generate health indicators, which are then combined to form a fused health indicator. The fused health indicator is used to determine the health stage of ECU ground line. The health stage is classified based on the relationship between ground line degradation level and the ECU communication loss status. The method was developed and validated using actual vehicle data.

How to Cite

Milhim, A., Ramadhan, H., Du, X., Jiang, S., & Sadjadi, H. (2023). Automotive Electronic Control Unit Ground Line Health Monitoring Method. Annual Conference of the PHM Society, 15(1). https://doi.org/10.36001/phmconf.2023.v15i1.3520
Abstract 454 | PDF Downloads 199

##plugins.themes.bootstrap3.article.details##

Keywords

Electronic Control Unit (ECU), Controller Area Network (CAN), Wiring, Conenctor, Vehicle, Automotive, Ground Fault, Degradation, Health Indicator, Health Stage, Health Status, Prognostics

References
Baldwin, T., Renovich, F., Saunders, L. F., & Lubkeman, D. (2001). Fault Locating in Ungrounded and High-Resistance Grounded Systems. TRANSACTIONS ON INDUSTRY APPLICATIONS,, 37(4), 1152-1159.

Bani Milhim, A., Ramadhan, H., Kazemi, H., Du, X., Jiang, S., & Sadjadi, H. (2022). Voltage-Based Physical Layer Fault Diagnosis for Controller Area Network. Annual Conference of the PHM Society, (pp. 1-8).

Du, X., Jiang, S., Nagose, A., Zhang, Y., & Wienckowski, N. (2016). Locating wire short fault for in-vehicle controller area network with resistance estimation approach. SAE International Journal of Passenger Cars-Electronic and Electrical Systems, 93-99.

Du, X., Jiang, S., Zhou, D., Bani Milhim, A., & Sadjadi, H. (2023). Ground Fault Diagnostics for Automotive Electronic Control Units. International Journal of Prognostics and Health Management, 1-13.

Gaona , C. A., Blázquez , F., & Frías , P. (2010). A Novel Rotor Ground-Fault-Detection Technique for Synchronous Machines With Static Excitation . IEEE Transactions on Energy Conversion, 25(4), 965 - 973 .

Gaona, C. A., Blazquez, F., Frías, P., & Redondo, M. (2010). A Novel Rotor Ground-Fault-Detection Technique for Synchronous Machines With Static Excitation. IEEE Transactions on Energy Conversion, 965-973.

Guerrero, J. M., Mahtani, K., Serrano-Jimenez, D., & Platero, C. A. (2021). Ground fault location method for DC power sources. IEEE 13th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED). Dallas, USA.

Infineon. (2007). High speed CAN Transceivers Application Note. Munchen, Germany.
ISO11898-2. (2016). ISO 11898-2:2016. Retrieved from https://www.iso.org/standard/67244.html.

Kumar, R., Vaijayanthi, A., Deshmukh, R., Vedik, B., & Shiva, C. K. (2022). A condition monitoring and fault detection in the windings of power transformer using impulse frequency response analysis. International Journal of System Assurance Engineering and Management, 66(4), 2062–2074.

Li, Y., Liu, K., & Meng, X. (2016). A single-line-to-ground fault diagnosis method in small-current--grounding system based on fuzzy-integral decision fusion technique. China International Conference on Electricity Distribution. Xi'an.
Matthias, M. (2007). US Patent No. 7257740B2.

Muth, M. (2005, December 1). USA Patent No. US20050268166 A1.
Pardo, A., Mahtani, K., Platero, C., & Sanchez-Fernandez, J. (2023). On-Line Rotor Ground Fault Location Method for Brushless

Synchronous Machines. IEEE Transactions on Industry Applications, 58(1), 3067-3076.

Richards, p. (2002). A CAN Physical Layer Discussion . Microchip Technology Inc. .

Robertson, T. (2014). Network diagnostic flow chart- how to troubleshoot vehicle level CAN communication and CAN diagnostic issues on Nissan and Infinity vehicles. Detroit, MI: SAE World Congress.

Tornare, J.-M., Costes, C., & Laurine, P. (2014). US Patent No. 20160240022.

Tornare, J.-M., COSTES, C., & LAURINE, P. (2014, December 25). USA Patent No. US20140375326 A1.
Section
Industry Experience Papers

Most read articles by the same author(s)

1 2 3 > >>